Show simple item record

dc.contributor.authorDamghani, Sahar
dc.date.accessioned2011-06-30T12:17:06Z
dc.date.available2012-06-20T15:43:10Z
dc.date.issued2011
dc.identifier.urihttp://hdl.handle.net/10713/548
dc.descriptionUniversity of Maryland, Baltimore. Biomedical Sciences-Dental School. M.S. 2011en_US
dc.description.abstractPurpose: to evaluate the effect of the number and distribution of dental implants on the occlusal pressure transmitted to the palate. Material and Methods: eight implant analogs were placed in a replica of maxilla in the areas of teeth number 3, 4, 5, 6, 11, 12, 13 and 14. Locator attachments were attached to the implant analogs. The distances between the centers of implant analogs on each side were 8 mm. Fifteen denture bases with occlusal rims were fabricated to fit on the maxillary replica. Under a load of 245 N, pressure on the palate was measured under each denture base in six different designs of Locator insertions: No Locators, 2 Locators, 4 Locators with distances of 8, 16, and 24 mm and 8 Locators. Data was analyzed using One-Way ANOVA and Tukey's HSD test. A p value of ≤0.05 was considered significant. Results: Pressure transmitted to the palate ranged from 20.67 +/- 16.06 N (mean +/- SD) for overdentures supported by 8 Locators to 85.61 +/- 27.94 N for a conventional denture (control). The amount of pressure transmitted to the palate when the overdentures were supported by 4 Locator attachments, was significantly lower than when no, or when two Locator attachments were used. However, they were not significantly different from each other. When the overdentures were supported by 8 locator attachments, the pressure transmitted to the palate was significantly lower than that of conventional dentures, overdentures supported by 2 Locator attachments and overdentures supported by 4 Locator attachments when the distance between the anterior and posterior implants was 8 mm. Conclusion: Using 4 Locator attachments produced significantly less pressure on the palate, compared to when zero or two Locators were used. When the distance between the 4 Locators was 16 or more mm, the pressure was not significantly lower than 8 Locator design, suggesting that the palate of a 4 implant-retained overdenture with a distance of 16 mm or more, does not contribute significantly to the pressure distribution under the overdenture. Considering the static nature of the load, the results of this study should be interpreted clinically with caution.en_US
dc.language.isoen_USen_US
dc.subjectimplanten_US
dc.subjectimplant retaineden_US
dc.subjectloaden_US
dc.subjectmaxillary overdentureen_US
dc.subjectpalatelessen_US
dc.subject.meshDental Implantsen_US
dc.subject.meshDenture, Overlayen_US
dc.subject.meshPalateen_US
dc.titleThe effect of number and distribution of maxillary implants on the load on the palate under implant-retained overdenturesen_US
dc.typedissertationen_US
dc.contributor.advisorMasri, Radi, 1975-
refterms.dateFOA2019-02-20T18:29:04Z


Files in this item

Thumbnail
Name:
Damghani_umaryland_0373N_10187.pdf
Size:
2.712Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record