The UMB Digital Archive is getting an upgrade! The upgrade requires a content freeze starting 1/27/25 and is expected to last two weeks. Any new user accounts or submissions made to the Archive during this time will not be transferred to the upgraded site. Contact ArchiveHelp@hshsl.umaryland.edu for questions.

Show simple item record

dc.contributor.authorRollor, Corey
dc.date.accessioned2024-09-26T18:08:56Z
dc.date.available2024-09-26T18:08:56Z
dc.date.issued2024
dc.identifier.urihttp://hdl.handle.net/10713/22860
dc.descriptionUniversity of Maryland, Baltimore, School of Dentistry. M.S. 2024.en_US
dc.description.abstractThe purpose of this study was to compare the accuracy and efficiency of fully guided static and dynamic computer-assisted surgical navigation methods for osteotomy and root-end resection (RER). Fifty root specimens from cadaver heads were divided into two groups: fully guided static computer-assisted endodontic microsurgery (FG sCAEMS) and dynamic computer-assisted endodontic microsurgery (dCAEMS) (n=25). Cone-beam computed tomography (CBCT) scans were conducted before and after the surgery. Osteotomy and RER were virtually planned in the preoperative CBCT scan. Endodontic microsurgery was executed with the guidance of 3D-printed surgical guides in FG sCAEMS and a 3D-dynamic navigation system in dCAEMS. Analysis involved calculating 2D and 3D deviations as well as angular deflection. Additionally, osteotomy volume, resected root length, and recording osteotomy and RER time were measured. The number of procedural errors were recorded. FG sCAEMS demonstrated comparable accuracy to dCAEMS, with no significant difference in 2D and 3D deviation values or angular deflection (P > .05). FG sCAEMS led to reduced osteotomy and RER times (P < .05). However, FG sCAEMS exhibited a higher incidence of incomplete RERs compared to dCAEMS. Osteotomy volume, RER angle, and resected root length were similar in both groups (P > .05). Overall, both FG sCAEMS and dCAEMS proved to be viable options for performing osteotomy and RER. Within the constraints of this study based on cadaver samples, FG sCAEMS demonstrated comparable accuracy to dCAEMS and both methods were efficient for performing osteotomy and RER.en_US
dc.language.isoen_USen_US
dc.subject.meshMicrosurgeryen_US
dc.subject.meshRoot Canal Therapyen_US
dc.subject.meshSurgical Navigation Systemsen_US
dc.subject.meshSurgery, Computer-Assisteden_US
dc.subject.meshCone-Beam Computed Tomographyen_US
dc.titleA Cadaver-based Comparison of Sleeve-guided Implant-drill and Dynamic Navigation Osteotomy and Root-end Resectionsen_US
dc.typedissertationen_US
dc.date.updated2024-09-12T19:09:50Z
dc.language.rfc3066en
dc.contributor.advisorMartinho, Frederico C.
refterms.dateFOA2024-09-26T18:08:57Z