• Login
    View Item 
    •   UMB Digital Archive
    • UMB Open Access Articles
    • UMB Open Access Articles
    • View Item
    •   UMB Digital Archive
    • UMB Open Access Articles
    • UMB Open Access Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UMB Digital ArchiveCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    Display statistics

    Outcomes in ED patients with non-specific ECG findings and low high-sensitivity troponin.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Alshaikh, Lamees M
    Apple, Fred S
    Christenson, Robert H
    deFilippi, Christopher R
    Limkakeng, Alexander T
    McCord, James
    Nowak, Richard M
    Singer, Adam J
    Peacock, W Frank
    Date
    2022-11-17
    Journal
    Journal of the American College of Emergency Physicians open
    Type
    Article
    
    Metadata
    Show full item record
    See at
    https://doi.org/10.1002/emp2.12844
    Abstract
    Background: Although some emergency department risk stratification tools consider non-specific ECG findings as an aid in disposition decisions, their clinical value in patients with an initially low high-sensitivity cardiac troponin I (hsTnI) is unclear. Objective: Our purpose was to determine if non-specific ECG (ns-ECG) findings are associated with 30-day major adverse cardiac events (MACE) in ED patients presenting with suspected acute coronary syndromes (ACS) who have a low initial hsTnI. Methods: Using the prospective Siemens Atellica hsTnI Food and Drug Administration submission observational database, we conducted a retrospective cohort study of the association between ns-ECG findings (defined as left bundle branch block [LBBB], ST depression [STD], or T-wave inversions [TWI]) and 30-day MACE (death, myocardial infarction, heart failure hospitalization, or coronary revascularization). Eligible patients presented with suspected ACS to one of 29 US EDs from April 2015 to April 2016, had stable vital signs, a blood sample for hsTnI (Siemen's Atellica, Siemens Healthineers, Inc, Malvern, PA) obtained at 1, 3, and 6 hours after ED presentation, and were followed for 30 days. The relationship between 30-day outcome, initial hsTnI, and ns-ECG was evaluated using chi-square testing. Results: Of 2676 enrolled, 1313 patients met the inclusion criteria and are included in the analysis. Median (interquartile range) age was 62 years (54, 72), 54% were male, with 56% white, and 39% African American. Median (interquartile range) times from symptom onset to presentation and presentation to specimen collection were 92 (0, 216) and 146 (117, 177) minutes, respectively. The most common presenting symptoms were chest pain (84%), followed by dyspnea (9%). ECG findings were categorized as T-wave inversion or non-specific T wave changes (42%), ST depression ns-ECG ST changes (16%), or LBBB (2%). Thirty-day MACE occurred in 72 (5.5%) patients, with coronary revascularization (35 patients, 2.7%) and heart failure (25 patients, 1.9%) being the most frequent outcomes. In patients with an initial hsTnI below the limit of quantitation (LOQ) of 2.5 ng/L (n = 449), there was no association between ns-ECG changes and 30-day MACE (P = 0.42). If the hsTnI was ≥LOQ (2.5 ng/L), there were increased rates of 30-day MACE and ns-ECG findings (P = 0.01). Conclusion: In ED suspected ACS patients without unstable vital signs, and an initial hsTnI less than the LOQ (2.5 ng/L), ns-ECG findings are not associated with 30-day major adverse cardiac events. The use of ns-ECG findings in ACS disposition should be considered in the context of hsTnI levels.
    Rights/Terms
    © 2022 The Authors. JACEP Open published by Wiley Periodicals LLC on behalf of American College of Emergency Physicians.
    Keyword
    ACS
    Emergency
    High‐sensitivity cardiac troponin
    LBBB
    MACE
    ST depressions
    T‐wave inversions
    hsTnI
    non‐specific ECG findings
    Identifier to cite or link to this item
    http://hdl.handle.net/10713/20246
    ae974a485f413a2113503eed53cd6c53
    10.1002/emp2.12844
    Scopus Count
    Collections
    UMB Open Access Articles

    entitlement

    Related articles

    • Myocardial Infarction Can Be Safely Excluded by High-sensitivity Troponin I Testing 3 Hours After Emergency Department Presentation.
    • Authors: Peacock WF, Christenson R, Diercks DB, Fromm C, Headden GF, Hogan CJ, Kulstad EB, LoVecchio F, Nowak RM, Schrock JW, Singer AJ, Storrow AB, Straseski J, Wu AHB, Zelinski DP
    • Issue date: 2020 Aug
    • Prehospital Modified HEART Score Predictive of 30-Day Adverse Cardiac Events.
    • Authors: Stopyra JP, Harper WS, Higgins TJ, Prokesova JV, Winslow JE, Nelson RD, Alson RL, Davis CA, Russell GB, Miller CD, Mahler SA
    • Issue date: 2018 Feb
    • Troponin elevations only detected with a high-sensitivity assay: clinical correlations and prognostic significance.
    • Authors: Korley FK, Schulman SP, Sokoll LJ, DeFilippis AP, Stolbach AI, Bayram JD, Saheed MO, Omron R, Fernandez C, Lwin A, Cai SS, Post WS, Jaffe AS
    • Issue date: 2014 Jul
    • Undetectable Concentrations of a Food and Drug Administration-approved High-sensitivity Cardiac Troponin T Assay to Rule Out Acute Myocardial Infarction at Emergency Department Arrival.
    • Authors: McRae AD, Innes G, Graham M, Lang E, Andruchow JE, Ji Y, Vatanpour S, Abedin T, Yang H, Southern DA, Wang D, Seiden-Long I, DeKoning L, Kavsak P
    • Issue date: 2017 Oct
    • Predictive value of T-wave abnormalities at the time of emergency department presentation in patients with potential acute coronary syndromes.
    • Authors: Lin KB, Shofer FS, McCusker C, Meshberg E, Hollander JE
    • Issue date: 2008 Jun
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Policies | Contact Us | UMB Health Sciences & Human Services Library
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.