• Login
    View Item 
    •   UMB Digital Archive
    • UMB Open Access Articles
    • UMB Open Access Articles
    • View Item
    •   UMB Digital Archive
    • UMB Open Access Articles
    • UMB Open Access Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UMB Digital ArchiveCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    Display statistics

    Total Body Irradiation in Haematopoietic Stem Cell Transplantation for Paediatric Acute Lymphoblastic Leukaemia: Review of the Literature and Future Directions.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Hoeben, Bianca A W
    Wong, Jeffrey Y C
    Fog, Lotte S
    Losert, Christoph
    Filippi, Andrea R
    Bentzen, Søren M
    Balduzzi, Adriana
    Specht, Lena
    Date
    2021-12-03
    Journal
    Frontiers in Pediatrics
    Publisher
    Frontiers Media S.A.
    Type
    Article
    
    Metadata
    Show full item record
    See at
    https://doi.org/10.3389/fped.2021.774348
    Abstract
    Total body irradiation (TBI) has been a pivotal component of the conditioning regimen for allogeneic myeloablative haematopoietic stem cell transplantation (HSCT) in very-high-risk acute lymphoblastic leukaemia (ALL) for decades, especially in children and young adults. The myeloablative conditioning regimen has two aims: (1) to eradicate leukaemic cells, and (2) to prevent rejection of the graft through suppression of the recipient's immune system. Radiotherapy has the advantage of achieving an adequate dose effect in sanctuary sites and in areas with poor blood supply. However, radiotherapy is subject to radiobiological trade-offs between ALL cell destruction, immune and haematopoietic stem cell survival, and various adverse effects in normal tissue. To diminish toxicity, a shift from single-fraction to fractionated TBI has taken place. However, HSCT and TBI are still associated with multiple late sequelae, leaving room for improvement. This review discusses the past developments of TBI and considerations for dose, fractionation and dose-rate, as well as issues regarding TBI setup performance, limitations and possibilities for improvement. TBI is typically delivered using conventional irradiation techniques and centres have locally developed heterogeneous treatment methods and ways to achieve reduced doses in several organs. There are, however, limitations in options to shield organs at risk without compromising the anti-leukaemic and immunosuppressive effects of conventional TBI. Technological improvements in radiotherapy planning and delivery with highly conformal TBI or total marrow irradiation (TMI), and total marrow and lymphoid irradiation (TMLI) have opened the way to investigate the potential reduction of radiotherapy-related toxicities without jeopardising efficacy. The demonstration of the superiority of TBI compared with chemotherapy-only conditioning regimens for event-free and overall survival in the randomised For Omitting Radiation Under Majority age (FORUM) trial in children with high-risk ALL makes exploration of the optimal use of TBI delivery mandatory. Standardisation and comprehensive reporting of conventional TBI techniques as well as cooperation between radiotherapy centres may help to increase the ratio between treatment outcomes and toxicity, and future studies must determine potential added benefit of innovative conformal techniques to ultimately improve quality of life for paediatric ALL patients receiving TBI-conditioned HSCT.
    Rights/Terms
    Copyright © 2021 Hoeben, Wong, Fog, Losert, Filippi, Bentzen, Balduzzi and Specht.
    Keyword
    acute lymphoblastic leukaemia (ALL)
    haematopoietic stem cell transplantation (HSCT)
    paediatric
    total body irradiation (TBI)
    total lymph node irradiation (TLI)
    total marrow and lymphatic irradiation
    total marrow irradiation (TMI)
    Identifier to cite or link to this item
    http://hdl.handle.net/10713/17559
    ae974a485f413a2113503eed53cd6c53
    10.3389/fped.2021.774348
    Scopus Count
    Collections
    UMB Open Access Articles

    entitlement

    Related articles

    • Targeted total marrow irradiation using three-dimensional image-guided tomographic intensity-modulated radiation therapy: an alternative to standard total body irradiation.
    • Authors: Wong JY, Liu A, Schultheiss T, Popplewell L, Stein A, Rosenthal J, Essensten M, Forman S, Somlo G
    • Issue date: 2006 Mar
    • Total body irradiation in allogeneic bone marrow transplantation conditioning regimens: A review.
    • Authors: Paix A, Antoni D, Waissi W, Ledoux MP, Bilger K, Fornecker L, Noel G
    • Issue date: 2018 Mar
    • Total marrow irradiation (TMI): Addressing an unmet need in hematopoietic cell transplantation - a single institution experience review.
    • Authors: Wong JYC, Liu A, Han C, Dandapani S, Schultheiss T, Palmer J, Yang D, Somlo G, Salhotra A, Hui S, Al Malki MM, Rosenthal J, Stein A
    • Issue date: 2022
    • ESTRO ACROP and SIOPE recommendations for myeloablative Total Body Irradiation in children.
    • Authors: Hoeben BAW, Pazos M, Seravalli E, Bosman ME, Losert C, Albert MH, Boterberg T, Ospovat I, Mico Milla S, Demiroz Abakay C, Engellau J, Jóhannesson V, Kos G, Supiot S, Llagostera C, Bierings M, Scarzello G, Seiersen K, Smith E, Ocanto A, Ferrer C, Bentzen SM, Kobyzeva DA, Loginova AA, Janssens GO
    • Issue date: 2022 Aug
    • Total Body Irradiation Forever? Optimising Chemotherapeutic Options for Irradiation-Free Conditioning for Paediatric Acute Lymphoblastic Leukaemia.
    • Authors: Ben Hassine K, Powys M, Svec P, Pozdechova M, Versluys B, Ansari M, Shaw PJ
    • Issue date: 2021

    Related items

    Showing items related by title, author, creator and subject.

    • Thumbnail

      Use of CT simulation and 3-D radiation therapy treatment planning system to develop and validate a total-body irradiation technique for the New Zealand White rabbit

      Poirier, Yannick; Prado, Charlotte; Prado, Karl; Draeger, Emily; Jackson, Isabel L; Vujaskovic, Zeljko (Taylor and Francis Inc., 2020-09-24)
      The optimal technique irradiates animals on the left-decubitus position using two isocentric bilateral parallel-opposed 6 MV x-ray beams. Placement of a 5 mm bolus and 8.5 mm beam spoiler was shown to increase the dose to within ≤5 mm of the surface, improving dose homogeneity throughout the body of the rabbit. A simple hand calculation formalism, dependent only on mid-abdominal separation, could be used to calculate the number of monitor units (MUs) required to accurately deliver the prescribed dose to the animal. For the representative animal, the total body volume receiving > 95% of the dose, V95% > 99%, V100% > 95%, and V107% < 20%. The area of the body receiving >107% of the prescribed dose was mainly within the limbs, head, and around the lungs of the animal, where the smaller animal width reduces the x-ray attenuation. Individual organs were contoured by an experienced dosimetrist, and each received doses within 95-107% of the intended dose, with mean values ∼104%. Only the bronchus showed a maximal dose >107% (113%) due to the decreased attenuation of the lungs. To validate the technique, twenty animals were irradiated with four optically-stimulated luminescence dosimeters (OSLDs) placed on the surface of each animal (two on each side in the center of the radiation beam). The average dose over all animals was within <0.1% from intended values, with no animal receiving an average dose more than ±3.1% from prescription.
    • Thumbnail

      Total Body Irradiation in Haematopoietic Stem Cell Transplantation for Paediatric Acute Lymphoblastic Leukaemia: Review of the Literature and Future Directions.

      Hoeben, Bianca A W; Wong, Jeffrey Y C; Fog, Lotte S; Losert, Christoph; Filippi, Andrea R; Bentzen, Søren M; Balduzzi, Adriana; Specht, Lena (Frontiers Media S.A., 2021-12-03)
      Total body irradiation (TBI) has been a pivotal component of the conditioning regimen for allogeneic myeloablative haematopoietic stem cell transplantation (HSCT) in very-high-risk acute lymphoblastic leukaemia (ALL) for decades, especially in children and young adults. The myeloablative conditioning regimen has two aims: (1) to eradicate leukaemic cells, and (2) to prevent rejection of the graft through suppression of the recipient's immune system. Radiotherapy has the advantage of achieving an adequate dose effect in sanctuary sites and in areas with poor blood supply. However, radiotherapy is subject to radiobiological trade-offs between ALL cell destruction, immune and haematopoietic stem cell survival, and various adverse effects in normal tissue. To diminish toxicity, a shift from single-fraction to fractionated TBI has taken place. However, HSCT and TBI are still associated with multiple late sequelae, leaving room for improvement. This review discusses the past developments of TBI and considerations for dose, fractionation and dose-rate, as well as issues regarding TBI setup performance, limitations and possibilities for improvement. TBI is typically delivered using conventional irradiation techniques and centres have locally developed heterogeneous treatment methods and ways to achieve reduced doses in several organs. There are, however, limitations in options to shield organs at risk without compromising the anti-leukaemic and immunosuppressive effects of conventional TBI. Technological improvements in radiotherapy planning and delivery with highly conformal TBI or total marrow irradiation (TMI), and total marrow and lymphoid irradiation (TMLI) have opened the way to investigate the potential reduction of radiotherapy-related toxicities without jeopardising efficacy. The demonstration of the superiority of TBI compared with chemotherapy-only conditioning regimens for event-free and overall survival in the randomised For Omitting Radiation Under Majority age (FORUM) trial in children with high-risk ALL makes exploration of the optimal use of TBI delivery mandatory. Standardisation and comprehensive reporting of conventional TBI techniques as well as cooperation between radiotherapy centres may help to increase the ratio between treatment outcomes and toxicity, and future studies must determine potential added benefit of innovative conformal techniques to ultimately improve quality of life for paediatric ALL patients receiving TBI-conditioned HSCT. Copyright © 2021 Hoeben, Wong, Fog, Losert, Filippi, Bentzen, Balduzzi and Specht.
    • Thumbnail

      ESTRO ACROP and SIOPE recommendations for myeloablative Total Body Irradiation in children.

      Hoeben, Bianca A W; Pazos, Montserrat; Seravalli, Enrica; Bosman, Mirjam E; Losert, Christoph; Albert, Michael H; Boterberg, Tom; Ospovat, Inna; Mico Milla, Soraya; Demiroz Abakay, Candan; et al. (Elsevier, 2022-05-31)
      Background and purpose: Myeloablative Total Body Irradiation (TBI) is an important modality in conditioning for allogeneic hematopoietic stem cell transplantation (HSCT), especially in children with high-risk acute lymphoblastic leukemia (ALL). TBI practices are heterogeneous and institution-specific. Since TBI is associated with multiple late adverse effects, recommendations may help to standardize practices and improve the outcome versus toxicity ratio for children. Material and methods: The European Society for Paediatric Oncology (SIOPE) Radiotherapy TBI Working Group together with ESTRO experts conducted a literature search and evaluation regarding myeloablative TBI techniques and toxicities in children. Findings were discussed in bimonthly virtual meetings and consensus recommendations were established. Results: Myeloablative TBI in HSCT conditioning is mostly performed for high-risk ALL patients or patients with recurring hematologic malignancies. TBI is discouraged in children <3-4 years old because of increased toxicity risk. Publications regarding TBI are mostly retrospective studies with level III-IV evidence. Preferential TBI dose in children is 12-14.4 Gy in 1.6-2 Gy fractions b.i.d. Dose reduction should be considered for the lungs to <8 Gy, for the kidneys to ≤10 Gy, and for the lenses to <12 Gy, for dose rates ≥6 cGy/min. Highly conformal techniques i.e. TomoTherapy and VMAT TBI or Total Marrow (and/or Lymphoid) Irradiation as implemented in several centers, improve dose homogeneity and organ sparing, and should be evaluated in studies. Conclusions: These ESTRO ACROP SIOPE recommendations provide expert consensus for conventional and highly conformal myeloablative TBI in children, as well as a supporting literature overview of TBI techniques and toxicities.
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Policies | Contact Us | UMB Health Sciences & Human Services Library
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.