• Login
    View Item 
    •   UMB Digital Archive
    • UMB Open Access Articles
    • UMB Open Access Articles
    • View Item
    •   UMB Digital Archive
    • UMB Open Access Articles
    • UMB Open Access Articles
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UMB Digital ArchiveCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    Display statistics

    Intraoperative fluorescence perfusion assessment should be corrected by a measured subject-specific arterial input function

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Elliott, J.T.
    Addante, R.R.
    Slobegean, G.-P.
    Date
    2020
    Journal
    Journal of biomedical optics
    Publisher
    SPIE
    Type
    Article
    
    Metadata
    Show full item record
    See at
    https://doi.org/10.1117/1.JBO.25.6.066002
    Abstract
    SIGNIFICANCE: The effects of varying the indocyanine green injection dose, injection rate, physiologic dispersion of dye, and intravenous tubing volume propagate into the shape and magnitude of the arterial input function (AIF) during intraoperative fluorescence perfusion assessment, thereby altering the observed kinetics of the fluorescence images in vivo. AIM: Numerical simulations are used to demonstrate the effect of AIF on metrics derived from tissue concentration curves such as peak fluorescence, time-to-peak (TTP), and egress slope. APPROACH: Forward models of tissue concentration were produced by convolving simulated AIFs with the adiabatic approximation to the tissue homogeneity model using input parameters representing six different tissue examples (normal brain, glioma, normal skin, ischemic skin, normal bone, and osteonecrosis). RESULTS: The results show that AIF perturbations result in variations in estimates of total intensity of up to 80% and TTP error of up to 200%, with the errors more dominant in brain, less in skin, and less in bone. Interestingly, error in ingress slope was as high as 60% across all tissue types. These are key observable parameters used in fluorescence imaging either implicitly by viewing the image or explicitly through intensity fitting algorithms. Correcting by deconvolving the image with a measured subject-specific AIF provides an intuitive means of visualizing the data while also removing the source of variance and allowing intra- and intersubject comparisons. CONCLUSIONS: These results suggest that intraoperative fluorescence perfusion assessment should be corrected by patient-specific AIFs measured by pulse dye densitometry.
    Keyword
    angiography
    arterial input function
    fluorescence
    indocyanine green
    perfusion
    tracer kinetics
    Identifier to cite or link to this item
    https://www.scopus.com/inward/record.uri?eid=2-s2.0-85086355964&doi=10.1117%2f1.JBO.25.6.066002&partnerID=40&md5=77f172728cd6e5c83b26d34f6c717bb0; http://hdl.handle.net/10713/13134
    ae974a485f413a2113503eed53cd6c53
    10.1117/1.JBO.25.6.066002
    Scopus Count
    Collections
    UMB Open Access Articles

    entitlement

    Related articles

    • Repeatability of arterial input functions and kinetic parameters in muscle obtained by dynamic contrast enhanced MR imaging of the head and neck.
    • Authors: Koopman T, Martens RM, Lavini C, Yaqub M, Castelijns JA, Boellaard R, Marcus JT
    • Issue date: 2020 May
    • Evaluation of an automated method for arterial input function detection for first-pass myocardial perfusion cardiovascular magnetic resonance.
    • Authors: Jacobs M, Benovoy M, Chang LC, Arai AE, Hsu LY
    • Issue date: 2016 Apr 8
    • Semi-parametric arterial input functions for quantitative dynamic contrast enhanced magnetic resonance imaging in mice.
    • Authors: Taxt T, Reed RK, Pavlin T, Rygh CB, Andersen E, Jiřík R
    • Issue date: 2018 Feb
    • Automated detection of the arterial input function using normalized cut clustering to determine cerebral perfusion by dynamic susceptibility contrast-magnetic resonance imaging.
    • Authors: Yin J, Sun H, Yang J, Guo Q
    • Issue date: 2015 Apr
    • Evaluation of signal formation in local arterial input function measurements of dynamic susceptibility contrast MRI.
    • Authors: Bleeker EJ, Webb AG, van Walderveen MA, van Buchem MA, van Osch MJ
    • Issue date: 2012 May
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Policies | Contact Us | UMB Health Sciences & Human Services Library
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.